Partecipanti: Francesco R, Ombretta, Antonio, Despina, Francesco Nozzoli, Gaetano, Giancarlo, Lasse Hertle, Luisa, Marcello, Marco G, Rosario, Paola, Marco B, Kristian, Luigi Ernesto, Edoardo, Cristina, Daniele
Talks by F. Riggi and L. Hertle:
- POLA-BBS correlation was done with the red graph on the left plot of Lasse slide 6
- the distance (eve 100 km) should not play any role when correlating muon and neutron data
- Neutron detector measurement at different latitude (Franco's slides) were done with similar detectors
- Corrections for pressure and humidity (at low energy) were applied to neutron data.
- Is the effect larger for neutron detector than muon detector? It seems so, neutron detector should be more sensitive to the lower part of the primary energy spectrum
- For muons we only applied pressure corrections and cuts. We would like to improve corrections for the next iterations.
Talk by P. La Rocca
- it is important to compare new results with the old one done with POLA-01 also in view of planning for new measurements with POLA-02
- link to POLA-01 published data: https://eee.centrofermi.it/images/Data/dataLatFin.txt
Talk by F. Noferini
- a clarification: efficiencies directly depend on temperature (as shown also by Paola)
There are minutes attached to this event.
Show them.